Productivity2000 relay output module, 16-point, 6.25 - 24 VDC, 6 - 240 VAC, FORM A (SPST), 2 common(s), 8 point(s) per common, 1A / point, 8A / common @ 60 deg C for both VAC and VDC per point, FORM A (SPST), external fusing 8A max (user supplied). Requires removable terminal block (sold separately, P2-RTB or P2-RTB-1); optional ZIPLink connector modules and pre-wired cables are available. Learn More
Productivity2000 relay output module, 8-point, 6.25 - 24 VDC, 6-120 VAC, (6) FORM A (SPST) relays, (2) FORM C (SPDT) relays, 8 common(s), isolated, 1 point(s) per common, 4A / point @ 60 deg C for VAC and VDC, 2A / point if used w/ ZIPLink cable per point, external fusing 6.3A max (user supplied). Requires removable terminal block (sold separately, P2-RTB or P2-RTB-1); optional ZIPLink connector modules and pre-wired cables are available. Learn More
CPU Option Slot Module, Analog Input: 4-channel, voltage, Analog Output: 2-channel, voltage, Discrete Input: 4-point, Discrete Output: 4-point, relay, (4) Form A (SPST) relays. Learn More
CPU Option Slot Module, Analog Input: 4-channel, voltage, Analog Output: 2-channel, voltage, Discrete Input: 4-point, sinking/sourcing, Discrete Output: 4-point, relay, (4) Form A (SPST) relays. Learn More
CPU Option Slot Module, Analog Input: 4-channel, current, Analog Output: 2-channel, current, Discrete Input: 4-point, Discrete Output: 4-point, relay, (4) Form A (SPST) relays. Learn More
CPU Option Slot Module, Analog Input: 4-channel, current, Analog Output: 2-channel, current, Discrete Input: 4-point, sinking/sourcing, Discrete Output: 4-point, relay, (4) Form A (SPST) relays. Learn More
CPU Option Slot Module, Analog Input: 2-channel, current/voltage, Analog Output: 2-channel, current/voltage, Discrete Input: 4-point, Discrete Output: 4-point, relay, (4) Form A (SPST) relays. Learn More
CPU Option Slot Module, Analog Input: 2-channel, current/voltage, Analog Output: 2-channel, current/voltage, Discrete Input: 4-point, sinking/sourcing, Discrete Output: 4-point, relay, (4) Form A (SPST) relays. Learn More
ProSense temperature transmitter, isolated, Type K thermocouple input, 0 to 2000 deg F fixed, 4-20 mA output, 8 to 35 VDC operating voltage, DIN Form B connection head mount, screw terminals. Learn More
input current signal range(s) of 0 - 20 mA, input voltage signal range(s) of 0 - 15 VDC, 0 - 30 VDC, (4) Form A (SPST) relay(s), 5A @ 250 VAC, 5A @ 30 VDC, 24 VDC / 24 VAC operating voltage, LED indication, plastic housing, 35 mm DIN rail or panel mount, removable screw terminal block(s). Learn More
DC to DC converter, 18 - 75 VDC input, 24 VDC output, 2.5A, 60W, plastic housing, 35 mm DIN mount, screw terminal, removable. DIN rail insert for panel mounting included. Learn More
DC to DC converter, 18 - 75 VDC input, 12 VDC output, 5A, 60W, plastic housing, 35 mm DIN mount, screw terminal, removable. DIN rail insert for panel mounting included. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 2-channel, current/voltage, Discrete Output: 4-point, sinking, Analog Output: 2-channel, current/voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 2-channel, current/voltage, Discrete Output: 4-point, relay, Analog Output: 2-channel, current/voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 4-channel, voltage, Discrete Output: 4-point, relay, Analog Output: 2-channel, voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 4-channel, current, Discrete Output: 4-point, relay, Analog Output: 2-channel, current. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 2-channel, current/voltage, Discrete Output: 4-point, sourcing, Analog Output: 2-channel, current/voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 4-channel, voltage, Discrete Output: 4-point, sourcing, Analog Output: 2-channel, voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 4-channel, current, Discrete Output: 4-point, sourcing, Analog Output: 2-channel, current. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 4-channel, voltage, Discrete Output: 4-point, sinking, Analog Output: 2-channel, voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, DC, Analog Input: 4-channel, current, Discrete Output: 4-point, sinking, Analog Output: 2-channel, current. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, AC, Analog Input: 4-channel, voltage, Discrete Output: 4-point, relay, Analog Output: 2-channel, voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, AC, Analog Input: 2-channel, current/voltage, Discrete Output: 4-point, relay, Analog Output: 2-channel, current/voltage. Learn More
CLICK Ethernet Analog PLC, 24 VDC required, Ethernet and serial ports, Discrete Input: 4-point, AC, Analog Input: 4-channel, current, Discrete Output: 4-point, relay, Analog Output: 2-channel, current. Learn More