Thermal overload relay bi-metallic adjustable FLA range 10- 15 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 7- 10 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 5.6- 8.0 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 2.8- 4.0 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 8- 12.5 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 4.0- 6.3 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 1.8- 2.8 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 1.2- 1.8 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.8- 1.2 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.56- 0.8 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.28- 0.4 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.43 - 0.63 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button Learn More
Electronic Solid State Relays adjustable FLA range 5- 25 A adjustable trip class 10,20,30 manual / automatic reset mode phase loss and phase unbalance protection 1 Normally Open / 1 Normally Close auxilary contacts Learn More
Electronic Solid State Relays adjustable FLA range 1.6 - 8 A adjustable trip class 10,20,30 manual / automatic reset mode phase loss and phase unbalance protection 1 Normally Open / 1 Normally Close auxilary contacts Learn More
Electronic Solid State Relays adjustable FLA range 0.4- 2 A adjustable trip class 10,20,30 manual / automatic reset mode phase loss and phase unbalance protection 1 Normally Open / 1 Normally Close auxilary contacts Learn More
Thermal overload relay bi-metallic adjustable FLA range 63 -80 Amps tripping class 10 phase loss sensitive , 50 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 57 -70 Amps tripping class 10 phase loss sensitive , 50 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 50 -63 Amps tripping class 10 phase loss sensitive , 50 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 40 -57 Amps tripping class 10 phase loss sensitive , 50 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 32-50 Amps tripping class 10 phase loss sensitive , 50 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 200 -310 Amps tripping class 10 phase loss sensitive , 155 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 140 -215 Amps tripping class 10 phase loss sensitive , 155 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 100 -150 Amps tripping class 10 phase loss sensitive , 155 mm frame hand/ Auto / Reset button Learn More
Thermal overload relay bi-metallic adjustable FLA range 22-32 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC025) Learn More
Thermal overload relay bi-metallic adjustable FLA range 15-23 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC025) Learn More
Thermal overload relay bi-metallic adjustable FLA range 11-17 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC025) Learn More
Thermal overload relay bi-metallic adjustable FLA range 10-15 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC025) Learn More
Thermal overload relay bi-metallic adjustable FLA range 7 -10 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC025) Learn More
Thermal overload relay bi-metallic adjustable FLA range 8.0 -12.5 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC025) Learn More
Thermal overload relay bi-metallic adjustable FLA range 11-17 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 10-15 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 7 -10 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 5.6 -8.0 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 2.8 -4.0 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 8.0 -12.5 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 4.0 -6.3 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 1.8 -2.8 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 1.2 -1.8 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.8 -1.2 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.56-0.8 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.28-0.4 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 0.4-0.63 Amps tripping class 10 phase loss sensitive , 45 mm frame hand/ Auto / Reset button (CWC07) Learn More
Thermal overload relay bi-metallic adjustable FLA range 90 -112Amps tripping class 10 phase loss sensitive , 75 mm frame hand/ Auto / Reset button Learn More